Properties |
Test Method |
Requirement |
Typical Data |
|
Physical Properties: |
||||
1 |
Tensile Strength |
ASTM D 638 |
Min. 10.4 Mpa |
13.5 Mpa |
2 |
Ultimate Elongation |
ASTM D 638 |
Min. 200% |
450% |
3 |
Longitudinal Change |
UL 224 |
± 10 % |
+3% to -5% |
4 |
Shrink Ratio |
IEC 811-1-1 |
2 : 1 |
2 : 1 |
Thermal Properties: |
||||
5 |
Continuous Operating Temperature |
|
|
-55°C to +135°C |
6 |
Shrink Temperature |
|
|
Min. 100°C |
7 |
Flammability* |
UL 224 VW-1 |
|
Pass |
8 |
Heat Shock (4 hrs at 250°C) |
UL 224 |
No Cracking |
Pass |
9 |
Cold Bend |
UL 224 |
No Cracking |
Pass |
10 |
Thermal Ageing (168 hrs at 158°C) |
UL 224 |
|
|
11 |
Tensile Strength |
|
Min 70% value of unaged specimen |
12.4 Mpa |
12 |
Ultimate Elongation |
|
Min 70% value of unaged specimen |
400% |
Electrical Properties: |
||||
14 |
Dielectric Strength |
IEC 243 |
20kV/mm |
25 kV/mm |
15 |
Volume Resistivity |
IEC 93 |
>1014 Ώ . cm |
Pass |
16 |
Chemical Properties: |
|
|
|
17 |
Water Absorption |
ASTM D 570 |
≤ 0.5% |
Pass |
18 |
Fluid Resistance |
ISO 175, MIL-1-23053/5 |
|
Pass |