SPECIFICATION SHEET


Characteristics

Requirement

Frequency

Control Method

 

Product Control

 

 

 

1

Visual

Good and free from defects

100% - daily

Internal

2

Dimensions

As per Engineering drawing

5% - daily

Internal

3

Tensile strength

min 12 MPa (N/mm2)

10 samples - daily

ASTM D 638

4

Ultimate elongation

min 300%

10 samples - daily

ASTM D 638

5

Environmental: 7 days outdoor at 15 PSI

No leakage at 15 PSI

1 installation - daily

Internal

6

Air Pressure Test : 30 PSI for 4 hours

No leakage

1 installation - daily

Internal

7

Hardness

min 45 Shore D

Daily

ASTM 2240

8

Tensile strength after thermal aging (120° C, 168 hours)

min 10 MPa (N/mm2)

Qualification

ISO - 188

9

Ultimate elongation after  thermal aging (120°C, 168 hours)

min 250%

Qualification

ISO - 188

10

Environmental Cycling - 8 cycles 6 hours at 60°C, 6 hours at -10°C. Pressurized at 10 PSI

No leakage at 10 PSI for 15 minutes

Qualification

Internal

11

Water absorption

max. 1%

Qualification

ISO - 62

12

Dielectric strength

min 12 kV/mm

Qualification

IEC - 243

13

Volume resistivity

min 1011 ohm-cm

Qualification

IEC - 93

 

Raw material Control

 

 

 

14

Carbon Black Content

min 2%

Qualification

BS 2 782 Method-452 B:1978

15

Tensile strength

min 12 MPa (N/mm2)

Compounding

ASTM D 638

16

Ultimate elongation

min 300%

Compounding

ASTM D 638

17

Hardness

min 45 Shore D

Compounding

ASTM 2240

 

 

Frequency

Agency

 

 

Daily

- Routine test during production

In - house

 

 

Qualification

- Whichever is earlier of the following

External & In - house

 

 

 

a. At the time of introduction of new product

 

 

 

 

b. After a significant change in formulation

 

 

 

 

c. Every three years

 

 

 

Compounding

- For compounding of every batch of material

External